Installation Instruction for all Models of Drop-In and Free Standing Ice Cooled Dispensers
©1994-2014, Cornelius Inc. - 7 - Publication Number: 166239001
REPLENISHING CO2
SUPPLY (AS REQUIRED)
NOTE: When indicator on the 1800-psi gage is in the shaded (“change CO2 cylinder”) portion of the
dial, CO
2 cylinder is almost empty and should be changed.
1. Fully close (clockwise) the CO
2 cylinder valve.
2. Slowly loosen the CO
2 regulator assembly coupling nut allowing CO2 pressure to escape, then remove the
regulator assembly from the empty CO
2 cylinder.
3. Unfasten safety chain and remove the empty CO
2 cylinder.
!
WARNING:
To avoid personnel injury and/or property damage, always secure the CO2 cylinder with a safety chain to prevent it
from falling over. Should the valve become accidently damaged or broken off, a CO
2 regulator can cause serious
personnel injury or death could occur.
4. Position the full CO
2 cylinder and secure with a safety chain.
5. Make sure gasket is in place inside the CO
2 regulator assembly coupling nut, then install the regulator
assembly on the CO
2 cylinder.
6. Open (counterclockwise) the CO
2 cylinder valve slightly to allow the lines to slowly fill with gas, then open
the valve fully to back-seat the valve (back-seating the valve prevents gas leakage around the valve shaft).
7. Check CO
2 connections for leaks. Tighten any loose connections.
CLEANING THE ICE BIN
1. Prepare a mild detergent soap solution in 100°F potable water.
2. Using a nylon (not wire) bristle brush, clean the cold plate and the interior of the ice bin with the soap solu-
tion.
3. Rinse the cold plate and interior bin surfaces with clean potable water.
4. Using a mechanical spray bottle, prepare a sanitizing solution according to the manufacturer’s directions
and spray the entire interior bin surfaces. Allow to air dry.
CONNECTING PRODUCT TO THE DISPENSER
NOTE: All inlet connections are clearly marked with a label adjacent to the inlet connections.
NOTE: Always leak check all connections.
Post–Mix units must have syrup, carbonated water and plain water connected. The number of syrups will depend
on the number of valves on the dispenser. Refer to the plumbing diagram for details of the hookup.
Pre-Mix units must have a pre-mix supply connected to each inlet for each valve to be supplied. Refer to the
plumbing diagram for details of the hook-up.
NOTE: A plumbing diagram when supplied with the unit, can be found in the dispensing tower.