Quest Elite 4000 Service Manual
© 2010-2015, Cornelius Inc. - 11 - Publication Number: 620048956SER
5. To change the BRIX setting, simply readjust the water flow rate. Located on
each of the valve assemblies inside the refrigerated compartment are the
adjusting screws for the water flow rate (one per valve).
If the BRIX reading is too high or low, rotate the appropriate water flow control
according to Figure 6. Repeat steps 1-5 until the proper BRIX setting is achieved.
Figure 6. BRIX Adjustment
IMPORTANT: When making changes to the water flow control, do not
rotate more than 1/4 turn per adjustment. Additionally,
prior to taking your next BRIX reading, momentarily
press the corresponding dispense button several times
prior to drawing a sample. This clears any remnants
from the dispense nozzle AND helps move the flow
control to its new setting.
Lemonade 5+1 10.5
Tropical Punch 5+1 11.8
Sweetened Ice Tea 7+1 6.0
Pineapple Juice 4+1 12.8
Prune Juice 2+1 16.0
Table 1.
Flavor Ratio BRIX
Dispense/Flush Lever
Water Flow
Controls
Comments to this Manuals