Page view 44
43
ZB Series
60 Hz
30
35
45
55
65
75
30
35
45
55
65
75
Q
P
ZB76KQE
Model
Evaporating Temperature
o
C
Performance Data
Q=Capacity (Watts) P=Power input (Watts) 1 & 3-Phase
-15
11750
9800
8500
4220
4730
5840
-5
17600
16650
14700
11650
9650
4340
4830
5960
7290
8820
0
21100
20000
17750
14550
12100
9600
4440
4920
6040
7390
8960
10740
5
25000
23750
21250
18300
15100
12050
4520
4980
6090
7450
9040
10880
15
28700
25050
21200
17150
5970
7300
8930
10840
10
29200
27800
24800
21550
18150
15000
4560
5000
6080
7430
9040
10930
-10
14450
13650
10800
9200
4250
4750
5890
7190
Condensing
Temperature
o
C
+ Max return gas temperature of 18.3°C in non shaded region
+ Max Suction superheat of 11K only in shaded region
+ Sub cooling 0K