5. FAULT FINDING
5.1 AIR COOLED MODEL
PROBLEM
No Product.
Product too cold.
Product
consistently too
warm.
Product too
warm after a
period of time.
Product too
warm during
peak periods.
ACTION
Check and correct.
Check and replace thermostat
if faulty.
Reduce the number of taps per
product.
Fit shorter coil.
Check fuse, plug and mains
switch.
Switch to ice bank.
Turn thermostat down.
Replace.
Replace base.
Plug pump into socket on the
base.
Replace.
Check for kinks. Clear out any
debris in the water recirculation
pipes.
Fit longer coil.
Check for space around the
cooler and airflow obstruction.
Clear and clean the condenser
fins.
Replace.
Replace base.
Reduce the number of products
on the cooler. Fit further cooler
if necessary.
Reduce the temperature of
product storage area.
POSSIBLE FAULT
Dispense system faulty.
Product frozen in coil.
Long soak time in coil
and/or python.
Coil too long.
No ice bank or water
bath too warm.
No water being
recirculated through
python.
Product coil too short.
Insufficient ice being
produced or being
produced very slowly.
Throughput too high.
POSSIBLE CAUSE
Is ice bank too large?
Low throughput.
Incorrectly specified.
Fuse blown or no electrical
supply.
Water bath thermostat used
but ice bank thermostat
needed.
Water bath thermostat set
too high.
Thermostat failed.
Refrigeration system failed.
Water recirculation pump
not plugged in.
Water recirculation pump
failed.
Blockage in python.
Incorrectly specified.
Poor airflow through the
condenser.
Condenser fan failed or
operating incorrectly.
Refrigeration system fault.
Too many coils in the cooler
for such a high demand.
Product inlet temperature
may be too high.