Page view 32
28 TD 184
Trouble RemedyProbable Cause
8. Unit off on reset Ice jams up in
evaporator shell
Clean inside
surface of
evaporator shell
Bin thermostat
will not shut off
machine. Set
too cold
Check and adjust or
replace
Auger motor
has worn
bearings
Check and replace
9. Unit goes off on
reset
Ice chute out of
alignment,
restricted ice
flow out of
evaporator
section
Re-align
Ice chute
center
separator bent
restricting ice
flow out of
evaporator
section
Replace ice chute
Incoming water
temperature too
cold
Maintain
temperature above
50° F
Bin thermostat
does not shut
off when bin is
full if ice
Replace bin
thermostat if
necessary
Mineral or scale
deposits on
inside of
evaporator shell
and evaporator
Inspect and clean